{"id":11216,"date":"2026-09-28T13:23:19","date_gmt":"2026-09-28T13:23:19","guid":{"rendered":"https:\/\/berndt-contec.de\/produkt\/ac2-5\/"},"modified":"2026-10-07T13:13:24","modified_gmt":"2026-10-07T13:13:24","slug":"ac2-5","status":"publish","type":"product","link":"https:\/\/berndt-contec.de\/en\/produkt\/ac2-5\/","title":{"rendered":"AC2-5"},"content":{"rendered":"\t\t<div data-elementor-type=\"product-post\" data-elementor-id=\"11216\" class=\"elementor elementor-11216 elementor-422\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-be1313c e-flex e-con-boxed e-con e-parent\" data-id=\"be1313c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38bd458b elementor-widget elementor-widget-text-editor\" data-id=\"38bd458b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Properties<\/h4><ul><li>Power supply<\/li><li>Auto-tuning function for PID control or two-point control<\/li><li>Main output via relay (12 A) and auxiliary output via 7 A relay<\/li><li>Inputs for 0\u20131 V, 0\/4\u201320 mA, PTC\/NTC10k, TC J\/K or PT100<\/li><li>Resolution 0.1 \/ 1\u00b0C or 1\u00b0F<\/li><li>Selection of cooling (dehumidification) or heating (humidification) function<\/li><li>Relative or absolute alarm thresholds, standby key on the front<\/li><li>Power-on limitation and safety function for sensor failure<\/li><li>Connection for LAE monitoring system TAB<\/li><\/ul><h4> <\/h4><h4>Applications<\/h4><ul><li>Heating system control<\/li><li>Climate zone control<\/li><li>Water baths<\/li><li>Ovens<\/li><li>Small cold rooms<\/li><li>Refrigerators<\/li><li>Refrigerated counters<\/li><\/ul><h4> <\/h4><h4>Advantages<\/h4><ul><li>2 independent outputs, ideal for air conditioning control<\/li><\/ul><h4> <\/h4><h4>Technical data<\/h4><table class=\"contec-tech-table\"><thead><tr><th colspan=\"1\"> <\/th><th colspan=\"1\">AC2-5TS2RW-B1BC<\/th><th colspan=\"1\">AC2-5PS2RW-B1BC<\/th><th colspan=\"1\">AC2-5PS1RW-1BC<\/th><th colspan=\"1\">AC2-5PS2RL-1BC<\/th><th colspan=\"1\">AC2-5JS2RW-B1BC<\/th><\/tr><\/thead><tbody><tr><td colspan=\"\" rowspan=\"\">Sensor type<\/td><td colspan=\"\" rowspan=\"\">NTC10k \/ PTC1000<\/td><td colspan=\"3\" rowspan=\"\">PT100<\/td><td colspan=\"\" rowspan=\"\">Thermocouple J \/ K<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Standard equipment<\/td><td colspan=\"\" rowspan=\"\">1 x SN4B20P1<\/td><td colspan=\"4\" rowspan=\"\">&#8211;<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Sensor measuring range<\/td><td colspan=\"\" rowspan=\"\">-40 to +120 \u00b0C<\/td><td colspan=\"4\" rowspan=\"\">Sensor-dependent<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Controller control range<\/td><td colspan=\"\" rowspan=\"\">-50 to +150 \u00b0C<\/td><td colspan=\"3\" rowspan=\"\">-100 \u00b0C to +850 \u00b0C<\/td><td colspan=\"\" rowspan=\"\">-50 to 999 \u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Resolution<\/td><td colspan=\"5\" rowspan=\"\">0.1\u00b0<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Terminals<\/td><td colspan=\"5\" rowspan=\"\">Screw terminals<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Output type<\/td><td colspan=\"5\" rowspan=\"\"> <\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 1 \/ Changeover contact<\/td><td colspan=\"5\" rowspan=\"\">12 (3.6)A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 2 \/ NO contact<\/td><td colspan=\"2\" rowspan=\"\">7 (1) A<\/td><td colspan=\"\" rowspan=\"\">&#8211;<\/td><td colspan=\"2\" rowspan=\"\">7 (1) A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Interface<\/td><td colspan=\"2\" rowspan=\"\">RS485<\/td><td colspan=\"2\" rowspan=\"\">&#8211;<\/td><td colspan=\"\" rowspan=\"\">RS485<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Power supply<\/td><td colspan=\"2\" rowspan=\"\">100 to 240 V<\/td><td colspan=\"2\" rowspan=\"\">&#8211;<\/td><td colspan=\"\" rowspan=\"\">100 to 240 V<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Dimensions WxHxD<\/td><td colspan=\"5\" rowspan=\"\">77 x 35 x 77 mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Installation dimensions WxH<\/td><td colspan=\"5\" rowspan=\"\">71x29mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Front protection rating<\/td><td colspan=\"5\" rowspan=\"\">IP 54<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Certification<\/td><td colspan=\"5\" rowspan=\"\">CE<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<h4>Universal Thermostat<\/h4>\n<p>The AC2-5 is a universal controller with two independent outputs. You can<br \/>\nselect the operating mode (heating\/cooling) for each channel in the menu, and choose whether<br \/>\nto control the channel via hysteresis or PID control! For<br \/>\neasy configuration, it features a guided parameter programming system<br \/>\nwhich ensures only the parameters required<br \/>\nfor the specific application are displayed. This makes programming<br \/>\nthe controller faster and more efficient. The AC2-5 also<br \/>\nincludes a standby (X) button and an info menu.    <\/p>\n","protected":false},"featured_media":11047,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[70],"product_tag":[],"class_list":["post-11216","product","type-product","status-publish","has-post-thumbnail","product_cat-thermostats","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11216","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/comments?post=11216"}],"version-history":[{"count":1,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11216\/revisions"}],"predecessor-version":[{"id":11217,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11216\/revisions\/11217"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media\/11047"}],"wp:attachment":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media?parent=11216"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_brand?post=11216"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_cat?post=11216"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_tag?post=11216"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}