{"id":11120,"date":"2026-09-28T13:23:21","date_gmt":"2026-09-28T13:23:21","guid":{"rendered":"https:\/\/berndt-contec.de\/produkt\/satconmicro-act\/"},"modified":"2026-10-07T13:01:30","modified_gmt":"2026-10-07T13:01:30","slug":"satconmicro-act","status":"publish","type":"product","link":"https:\/\/berndt-contec.de\/en\/produkt\/satconmicro-act\/","title":{"rendered":"SATCON<sup>MICRO-ACT<\/sup>"},"content":{"rendered":"\t\t<div data-elementor-type=\"product-post\" data-elementor-id=\"11120\" class=\"elementor elementor-11120 elementor-426\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7506926c e-flex e-con-boxed e-con e-parent\" data-id=\"7506926c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-46d605fe elementor-widget elementor-widget-text-editor\" data-id=\"46d605fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Properties<\/h4><ul><li>Power supply<\/li><li>Auto-tuning function for PID control or two-point control<\/li><li>Main output via relay 12(3.6)A and auxiliary output via relay 7(1)A<\/li><li>Inputs for PTC\/NTC10K<\/li><li>Resolution 0.1 \/ 1\u00b0C or 1\u00b0F<\/li><li>Selection of cooling or heating function<\/li><li>Relative or absolute alarm thresholds<\/li><li>Standby button on the front panel<\/li><li>Power-on limitation and safety function for sensor failure<\/li><li>Connection for LAE monitoring system TAB<\/li><\/ul><h4> <\/h4><h4>Applications<\/h4><ul><li>Small cold rooms<\/li><li>Refrigerators<\/li><li>Heating systems<\/li><li>Server room monitoring<\/li><\/ul><h4> <\/h4><h4>Advantages<\/h4><ul><li>2 independent outputs, ideal for air conditioning control<\/li><li>Hygiene Display<\/li><\/ul><h4> <\/h4><h4>Technical data<\/h4><table class=\"contec-tech-table\"><thead><tr><th colspan=\"1\"> <\/th><th colspan=\"1\">SATCON micro-ACT<\/th><\/tr><\/thead><tbody><tr><td colspan=\"\" rowspan=\"\">Sensor type<\/td><td colspan=\"\" rowspan=\"\">NTC10k \/ PTC1000 (KTY81-121)<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Standard equipment<\/td><td colspan=\"\" rowspan=\"\">1 x SN4B20P1<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Sensor measuring range<\/td><td colspan=\"\" rowspan=\"\">-40 \u00b0C &#8230; +120 \u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Electronics control range<\/td><td colspan=\"\" rowspan=\"\">-50 \u00b0C &#8230; +150 \u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Resolution<\/td><td colspan=\"\" rowspan=\"\">0.1\u00b0<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Terminals<\/td><td colspan=\"\" rowspan=\"\">Screw terminals<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Output type<\/td><td colspan=\"\" rowspan=\"\"> <\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 1 \/ N.O. contact<\/td><td colspan=\"\" rowspan=\"\">12(3.6)A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 2 \/ N.O. contact<\/td><td colspan=\"\" rowspan=\"\">7(1)A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Interface<\/td><td colspan=\"\" rowspan=\"\">RS485<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Power supply<\/td><td colspan=\"\" rowspan=\"\">100 &#8230; 240 Vac<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Dimensions WxHxD<\/td><td colspan=\"\" rowspan=\"\">110x53x75 mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Installation dimension<\/td><td colspan=\"\" rowspan=\"\">Wall surface mount<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Front protection rating<\/td><td colspan=\"\" rowspan=\"\">IP65<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Certification<\/td><td colspan=\"\" rowspan=\"\">CE<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<h4>Thermostat for wall mounting<\/h4>\n<p>The SATCON<sup>MICRO-ACT<\/sup> is a wall-mounting thermostat with a Hygiene Display and touch function.<br \/>\nIn the menu, you can select the operating mode (heating\/cooling) for each channel, as well as whether you wish to control the channel with hysteresis or PID control! For easy configuration, it is equipped with an assisted parameter programming system<br \/>\n, ensuring that only parameters relevant to the specifically selected application are displayed. This makes the<br \/>\ncontroller&#8217;s programming faster and more efficient. Naturally, a Standby (X) button and an info menu are also available.   <\/p>\n","protected":false},"featured_media":11041,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[70],"product_tag":[],"class_list":["post-11120","product","type-product","status-publish","has-post-thumbnail","product_cat-thermostats","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11120","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/comments?post=11120"}],"version-history":[{"count":1,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11120\/revisions"}],"predecessor-version":[{"id":11121,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11120\/revisions\/11121"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media\/11041"}],"wp:attachment":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media?parent=11120"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_brand?post=11120"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_cat?post=11120"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_tag?post=11120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}