{"id":11087,"date":"2026-09-28T13:23:09","date_gmt":"2026-09-28T13:23:09","guid":{"rendered":"https:\/\/berndt-contec.de\/produkt\/bit25\/"},"modified":"2026-10-07T12:30:19","modified_gmt":"2026-10-07T12:30:19","slug":"bit25","status":"publish","type":"product","link":"https:\/\/berndt-contec.de\/en\/produkt\/bit25\/","title":{"rendered":"BIT25"},"content":{"rendered":"\t\t<div data-elementor-type=\"product-post\" data-elementor-id=\"11087\" class=\"elementor elementor-11087 elementor-393\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-11f8e3cf e-flex e-con-boxed e-con e-parent\" data-id=\"11f8e3cf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-592255f9 elementor-widget elementor-widget-text-editor\" data-id=\"592255f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Properties<\/h4><ul><li>Up to 3 relays with a switching capacity of 20 A depending on the version<\/li><li>2 AUX outputs with 6 different operating modes<\/li><li>2 digital inputs with freely definable functions such as:<ul><li>Door contact<\/li><li>Alarm<\/li><li>Remote defrost start<\/li><li>Switching of parameter groups (ECO mode)<\/li><li>Connection of a third sensor (display sensor)<\/li><li>Setpoint adjustment via external potentiometer<\/li><\/ul><\/li><li>Light and standby control via M or ON\/OFF button<\/li><li>RS485 interface for integration into monitoring systems<\/li><\/ul><h4> <\/h4><h4>Applications<\/h4><ul><li>Beverage coolers<\/li><li>Plug-in display cases for shops and supermarkets<\/li><li>Refrigerators \/ freezers<\/li><li>Cold rooms<\/li><\/ul><h4> <\/h4><h4>Advantages<\/h4><ul><li>Multifunctional use in chilled and frozen areas<\/li><li>Stand-alone operation possible without display<\/li><li>External setpoint adjustment via potentiometer possible<\/li><\/ul><h4> <\/h4><h4>Technical data<\/h4><table class=\"contec-tech-table\"><thead><tr><th colspan=\"1\"> <\/th><th colspan=\"1\">BIT25B1S2E-B<\/th><th colspan=\"1\">BIT25B1S3E-B<\/th><\/tr><\/thead><tbody><tr><td colspan=\"\" rowspan=\"\">Sensor type<\/td><td colspan=\"\" rowspan=\"\">NTC 10k<\/td><td colspan=\"\" rowspan=\"\">NTC 10k<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Standard equipment<\/td><td colspan=\"\" rowspan=\"\">2 x SN4B20P1\u20262<\/td><td colspan=\"\" rowspan=\"\">2 x SN4B20P1\u20262<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Sensor measuring range<\/td><td colspan=\"\" rowspan=\"\">-40 \u2026 +105 \u00b0C<\/td><td colspan=\"\" rowspan=\"\">-40 \u2026 +105 \u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Controller regulation range<\/td><td colspan=\"\" rowspan=\"\">-50 \u00b0C \u2026 +110 \u00b0C<\/td><td colspan=\"\" rowspan=\"\">-50 \u00b0C \u2026 +110 \u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Resolution<\/td><td colspan=\"\" rowspan=\"\">0.1\u00b0<\/td><td colspan=\"\" rowspan=\"\">0.1\u00b0<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Input<\/td><td colspan=\"\" rowspan=\"\">DI1 + DI2<\/td><td colspan=\"\" rowspan=\"\">DI1 + DI2<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Potentiometer optional<\/td><td colspan=\"\" rowspan=\"\">Linear potentiometer 10 k\u03a9<\/td><td colspan=\"\" rowspan=\"\">Linear potentiometer 10 k\u03a9<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Terminals<\/td><td colspan=\"\" rowspan=\"\">Screw and plug-in terminals<\/td><td colspan=\"\" rowspan=\"\">Screw and plug-in terminals<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Output type<\/td><td colspan=\"\" rowspan=\"\"> <\/td><td colspan=\"\" rowspan=\"\"> <\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 1 \/ NO contact<\/td><td colspan=\"\" rowspan=\"\">20 (8) A compressor<\/td><td colspan=\"\" rowspan=\"\">20 (8) A compressor<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 2 \/ NO contact<\/td><td colspan=\"\" rowspan=\"\">16 (4) A AUX 1<\/td><td colspan=\"\" rowspan=\"\">16 (4) A AUX 1<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 3 \/ NO contact<\/td><td colspan=\"\" rowspan=\"\">&#8211;<\/td><td colspan=\"\" rowspan=\"\">7 (2) A AUX 2<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Interface<\/td><td colspan=\"\" rowspan=\"\">RS485<\/td><td colspan=\"\" rowspan=\"\">RS485<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Power supply<\/td><td colspan=\"\" rowspan=\"\">230 V AC<\/td><td colspan=\"\" rowspan=\"\">230 V AC<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Dimensions<\/td><td colspan=\"\" rowspan=\"\"> <\/td><td colspan=\"\" rowspan=\"\"> <\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">BIT25 WxHxD<\/td><td colspan=\"\" rowspan=\"\">86x82x44 mm<\/td><td colspan=\"\" rowspan=\"\">86x82x44 mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">LCD5-S WxHxD<\/td><td colspan=\"\" rowspan=\"\">77x35x20 mm<\/td><td colspan=\"\" rowspan=\"\">77x35x20 mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Installation dimensions<\/td><td colspan=\"\" rowspan=\"\"> <\/td><td colspan=\"\" rowspan=\"\"> <\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">BIT25<\/td><td colspan=\"\" rowspan=\"\">Wall mounting<\/td><td colspan=\"\" rowspan=\"\">Wall mounting<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">LCD5-S WxH<\/td><td colspan=\"\" rowspan=\"\">71&#215;29 mm<\/td><td colspan=\"\" rowspan=\"\">71&#215;29 mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Front protection class<\/td><td colspan=\"\" rowspan=\"\"> <\/td><td colspan=\"\" rowspan=\"\"> <\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">BIT25<\/td><td colspan=\"\" rowspan=\"\">IP 30<\/td><td colspan=\"\" rowspan=\"\">IP 30<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">LCD5-S<\/td><td colspan=\"\" rowspan=\"\">IP 55<\/td><td colspan=\"\" rowspan=\"\">IP 55<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Certification<\/td><td colspan=\"\" rowspan=\"\">CE<\/td><td colspan=\"\" rowspan=\"\">CE<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<h4>Split refrigeration controller for chilled + frozen \/ OEM<\/h4>\n<p>The BIT25 is a universal refrigeration controller for both chilled and frozen applications in a split design.<br \/>\nThe particularity lies in the multifunctional application area of this control system.<\/p>\n","protected":false},"featured_media":11088,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[66],"product_tag":[],"class_list":["post-11087","product","type-product","status-publish","has-post-thumbnail","product_cat-refrigeration-controller","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11087","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/comments?post=11087"}],"version-history":[{"count":1,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11087\/revisions"}],"predecessor-version":[{"id":11089,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11087\/revisions\/11089"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media\/11088"}],"wp:attachment":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media?parent=11087"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_brand?post=11087"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_cat?post=11087"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_tag?post=11087"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}