{"id":11078,"date":"2026-09-28T13:23:04","date_gmt":"2026-09-28T13:23:04","guid":{"rendered":"https:\/\/berndt-contec.de\/produkt\/ac1-27a\/"},"modified":"2026-10-07T12:27:42","modified_gmt":"2026-10-07T12:27:42","slug":"ac1-27a","status":"publish","type":"product","link":"https:\/\/berndt-contec.de\/en\/produkt\/ac1-27a\/","title":{"rendered":"AC1-27A"},"content":{"rendered":"\t\t<div data-elementor-type=\"product-post\" data-elementor-id=\"11078\" class=\"elementor elementor-11078 elementor-378\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-725d8cdc e-flex e-con-boxed e-con e-parent\" data-id=\"725d8cdc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-544e68f0 elementor-widget elementor-widget-text-editor\" data-id=\"544e68f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Properties<\/h4><ul><li>Auto-tuning function for PID control or on\/off control<\/li><li>Main output via 16(4)A relay or for SSR control and auxiliary output via 16(4)A relay<\/li><li>Input for 0-1V<\/li><li>Selection of dehumidification or humidification function<\/li><li>Relative or absolute alarm thresholds, standby key on the front<\/li><li>Start-up delay and safety function in case of sensor failure<\/li><li>Quick configuration via ZOT-AC1 programming device<\/li><li>Connection for LAE monitoring system TAB<\/li><\/ul><h4> <\/h4><h4>Applications<\/h4><ul><li>Greenhouse control<\/li><li>Cold rooms<\/li><li>Swimming pool humidification and dehumidification<\/li><li>Storage cells<\/li><li>Ripening cells<\/li><li>Air-conditioned rooms<\/li><\/ul><h4> <\/h4><h4>Advantages<\/h4><ul><li>2 independent outputs, ideal for greenhouse control<\/li><\/ul><h4> <\/h4><h4>Technical data<\/h4><table class=\"contec-tech-table\"><thead><tr><th colspan=\"1\"> <\/th><th colspan=\"1\">AC1-27AS2RE-B<\/th><\/tr><\/thead><tbody><tr><td colspan=\"\" rowspan=\"\">Sensor type<\/td><td colspan=\"\" rowspan=\"\">0 \u2026 1V<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Electronics control range<\/td><td colspan=\"\" rowspan=\"\">0 \u2026 100% r.H.<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Resolution<\/td><td colspan=\"\" rowspan=\"\">0.1\u00b0<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Terminals<\/td><td colspan=\"\" rowspan=\"\">Screw terminals<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 1 \/ Changeover<\/td><td colspan=\"\" rowspan=\"\">16 (4)A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 2 \/ Changeover<\/td><td colspan=\"\" rowspan=\"\">16 (4)A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Interface<\/td><td colspan=\"\" rowspan=\"\">RS485<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Power supply<\/td><td colspan=\"\" rowspan=\"\">230Vac<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Dimensions WxHxD<\/td><td colspan=\"\" rowspan=\"\">72x94x60mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Installation dimension<\/td><td colspan=\"\" rowspan=\"\">DIN rail<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Front protection class<\/td><td colspan=\"\" rowspan=\"\">IP 55<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Certification<\/td><td colspan=\"\" rowspan=\"\">CE<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<h4>Hygrostat for DIN rail<\/h4>\n<p>The AC1-27 is a universal hygrostat with two independent outputs.<br \/>\nIn the menu, you can select the operating mode (humidifying\/dehumidifying) for each channel, as well as whether you wish to control the channel with hysteresis or PID control!<br \/>\nFor easy configuration, it is equipped with a guided parameter programming system, so that only the parameters required for the specifically selected application are displayed.<br \/>\nThis makes programming the controller faster and more efficient.<br \/>\nThe two setpoints can be adjusted to requirements in an instant using the L1 and L2 keys.<br \/>\nNaturally, the AC1-27 also features a standby (I\/O) key and an info menu.<\/p>\n","protected":false},"featured_media":11068,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[67],"product_tag":[],"class_list":["post-11078","product","type-product","status-publish","has-post-thumbnail","product_cat-hygrostats","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11078","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/comments?post=11078"}],"version-history":[{"count":1,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11078\/revisions"}],"predecessor-version":[{"id":11079,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11078\/revisions\/11079"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media\/11068"}],"wp:attachment":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media?parent=11078"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_brand?post=11078"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_cat?post=11078"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_tag?post=11078"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}