{"id":11067,"date":"2026-09-28T13:23:04","date_gmt":"2026-09-28T13:23:04","guid":{"rendered":"https:\/\/berndt-contec.de\/produkt\/ac1-27\/"},"modified":"2026-10-07T12:25:44","modified_gmt":"2026-10-07T12:25:44","slug":"ac1-27","status":"publish","type":"product","link":"https:\/\/berndt-contec.de\/en\/produkt\/ac1-27\/","title":{"rendered":"AC1-27"},"content":{"rendered":"\t\t<div data-elementor-type=\"product-post\" data-elementor-id=\"11067\" class=\"elementor elementor-11067 elementor-377\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-16e38a78 e-flex e-con-boxed e-con e-parent\" data-id=\"16e38a78\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1222cdbf elementor-widget elementor-widget-text-editor\" data-id=\"1222cdbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Properties<\/h4><ul><li>Auto-tuning function for PID control or on\/off control<\/li><li>Main output via 16(4)A relay or for SSR control and auxiliary output via 16(4)A relay<\/li><li>Input PTC\/NTC10K, TC J\/K or Pt100<\/li><li>Resolution 0.1 \/ 1\u00b0C or 1\u00b0F<\/li><li>Selection of cooling or heating function<\/li><li>Relative or absolute alarm thresholds<\/li><li>Front standby key<\/li><li>Start-up limitation and safety function for sensor failure<\/li><li>Quick configuration via ZOT-AC1 programming tool<\/li><li>Connection for LAE monitoring system TAB<\/li><\/ul><h4> <\/h4><h4>Applications<\/h4><ul><li>Control of heating systems<\/li><li>Climate zone control<\/li><li>Water baths<\/li><li>Ovens<\/li><li>Small cold rooms<\/li><li>Refrigerators<\/li><li>Refrigerated counters<\/li><li>Laboratory systems<\/li><\/ul><h4> <\/h4><h4>Advantages<\/h4><ul><li>2 independent outputs, ideal for air conditioning control<\/li><\/ul><h4> <\/h4><h4>Technical data<\/h4><table class=\"contec-tech-table\"><thead><tr><th colspan=\"1\"> <\/th><th colspan=\"1\">AC1-27PS2RE-B<\/th><\/tr><\/thead><tbody><tr><td colspan=\"\" rowspan=\"\">Sensor type<\/td><td colspan=\"\" rowspan=\"\">PT100<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Controller range<\/td><td colspan=\"\" rowspan=\"\">-100 \u2026 850\u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Resolution<\/td><td colspan=\"\" rowspan=\"\">0.1\u00b0<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Terminals<\/td><td colspan=\"\" rowspan=\"\">Screw terminals<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 1 \/ changeover<\/td><td colspan=\"\" rowspan=\"\">16 (4)A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 2 \/ changeover<\/td><td colspan=\"\" rowspan=\"\">16 (4)A<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Interface<\/td><td colspan=\"\" rowspan=\"\">RS485<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Power supply<\/td><td colspan=\"\" rowspan=\"\">230Vac<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Dimensions WxHxD<\/td><td colspan=\"\" rowspan=\"\">72x94x60mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Mounting dimension<\/td><td colspan=\"\" rowspan=\"\">DIN rail<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Front protection class<\/td><td colspan=\"\" rowspan=\"\">IP 55<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Certification<\/td><td colspan=\"\" rowspan=\"\">CE<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<h4>DIN rail thermostat<\/h4>\n<p>The AC1-27 is a universal controller with two independent outputs.<br \/>\nYou can select the operating mode (heating\/cooling) for each channel in the menu, as well as whether you wish to control the channel with hysteresis or PID control!<br \/>\nFor easy configuration, it is equipped with a guided parameter programming system, so that only the parameters required for the specifically selected application are displayed.<br \/>\nThis makes programming the controller faster and more efficient.<br \/>\nThe two setpoints can be adjusted to requirements instantly using the L1 and L2 keys.<br \/>\nNaturally, the AC1-27 also features a standby (I\/O) key and an info menu.<\/p>\n","protected":false},"featured_media":11068,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[70],"product_tag":[],"class_list":["post-11067","product","type-product","status-publish","has-post-thumbnail","product_cat-thermostats","first","outofstock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11067","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/comments?post=11067"}],"version-history":[{"count":1,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11067\/revisions"}],"predecessor-version":[{"id":11069,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11067\/revisions\/11069"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media\/11068"}],"wp:attachment":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media?parent=11067"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_brand?post=11067"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_cat?post=11067"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_tag?post=11067"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}