{"id":11061,"date":"2026-09-28T13:23:09","date_gmt":"2026-09-28T13:23:09","guid":{"rendered":"https:\/\/berndt-contec.de\/produkt\/at2-5\/"},"modified":"2026-10-07T12:22:52","modified_gmt":"2026-10-07T12:22:52","slug":"at2-5","status":"publish","type":"product","link":"https:\/\/berndt-contec.de\/en\/produkt\/at2-5\/","title":{"rendered":"AT2-5"},"content":{"rendered":"\t\t<div data-elementor-type=\"product-post\" data-elementor-id=\"11061\" class=\"elementor elementor-11061 elementor-391\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2bdc228e e-flex e-con-boxed e-con e-parent\" data-id=\"2bdc228e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b14280d elementor-widget elementor-widget-text-editor\" data-id=\"3b14280d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Properties<\/h4><ul><li>Choice of cooling or heating function<\/li><li>Direct compressor control via 16(5)A high-power relay<\/li><li>Optimised evaporator fan control<\/li><li>Configurable auxiliary output for six operating modes<\/li><li>Selectable NTC10K or PTC input<\/li><li>Defrost via compressor stop, electric defrost or hot gas defrost<\/li><li>Alarm message for temperature and door opening<\/li><li>Optional light control button<\/li><li>Connection to monitoring systems such as LAE TAB<\/li><li>UL certified<\/li><\/ul><h4> <\/h4><h4>Applications<\/h4><ul><li>Small cold rooms<\/li><li>Refrigerators<\/li><\/ul><h4> <\/h4><h4>Advantages<\/h4><ul><li>Heating or cooling function \/ 2 parameter groups \/ door contact \/ ICEBANK<\/li><\/ul><h4> <\/h4><h4>Technical data<\/h4><table class=\"contec-tech-table\"><thead><tr><th colspan=\"1\"> <\/th><th colspan=\"1\">AT2-5BS4E-AG<\/th><th colspan=\"1\">AT2-5BS4E-1SB<\/th><\/tr><\/thead><tbody><tr><td colspan=\"\" rowspan=\"\">Sensor type<\/td><td colspan=\"\" rowspan=\"\">PTC1000 (KTY81-121) \/ NTC10k<\/td><td colspan=\"\" rowspan=\"\">PTC1000 (KTY81-121) \/ NTC10k<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Standard equipment<\/td><td colspan=\"\" rowspan=\"\">2 x SN4B20P1\u20262<\/td><td colspan=\"\" rowspan=\"\">1 x SN4B20P1<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Sensor measuring range<\/td><td colspan=\"\" rowspan=\"\">-40 \u2026 +105\u00b0C<\/td><td colspan=\"\" rowspan=\"\">-40 \u2026 +105\u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Controller regulation range<\/td><td colspan=\"\" rowspan=\"\">-50\u00b0C \u2026 +120\u00b0C<\/td><td colspan=\"\" rowspan=\"\">-50\u00b0C \u2026 +120\u00b0C<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Resolution<\/td><td colspan=\"\" rowspan=\"\">0.1\u00b0<\/td><td colspan=\"\" rowspan=\"\">0.1\u00b0<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Input<\/td><td colspan=\"\" rowspan=\"\">Door contact<\/td><td colspan=\"\" rowspan=\"\">Door contact<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Terminals<\/td><td colspan=\"\" rowspan=\"\">Screw terminals<\/td><td colspan=\"\" rowspan=\"\">Screw terminals<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Output type<\/td><td colspan=\"\" rowspan=\"\"> <\/td><td colspan=\"\" rowspan=\"\"> <\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 1 \/ NO contact<\/td><td colspan=\"\" rowspan=\"\">16 (5)A compressor<\/td><td colspan=\"\" rowspan=\"\">16 (5)A compressor<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 2 \/ NO contact<\/td><td colspan=\"\" rowspan=\"\">7 (2)A evaporator fan<\/td><td colspan=\"\" rowspan=\"\">7 (2)A evaporator fan<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Relay 3 \/ NO contact<\/td><td colspan=\"\" rowspan=\"\">7 (2)A AUX<\/td><td colspan=\"\" rowspan=\"\">7 (2)A AUX<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Interface<\/td><td colspan=\"\" rowspan=\"\">TTL<\/td><td colspan=\"\" rowspan=\"\">TTL<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Power supply<\/td><td colspan=\"\" rowspan=\"\">230Vac<\/td><td colspan=\"\" rowspan=\"\">230Vac<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Dimensions WxHxD<\/td><td colspan=\"\" rowspan=\"\">77x35x77mm<\/td><td colspan=\"\" rowspan=\"\">77x35x77mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Installation dimensions WxH<\/td><td colspan=\"\" rowspan=\"\">71x29mm<\/td><td colspan=\"\" rowspan=\"\">71x29mm<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Front protection rating<\/td><td colspan=\"\" rowspan=\"\">IP 55<\/td><td colspan=\"\" rowspan=\"\">IP 55<\/td><\/tr><tr><td colspan=\"\" rowspan=\"\">Certification<\/td><td colspan=\"\" rowspan=\"\">CE \/ UL<\/td><td colspan=\"\" rowspan=\"\">CE \/ UL<\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<h4>Refrigeration controller for chilled and frozen applications<\/h4>\n<p>The AT2-5 is a universal refrigeration controller for chilled and frozen storage.<br \/>\nThe AT2-5 ICE features a modified front panel.<br \/>\nThis was specifically designed for ICEBANK requirements.<br \/>\nWith this electronic system, the ICEBANK function can be activated manually via the ICE button according to customer requirements.<\/p>\n","protected":false},"featured_media":11062,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[66],"product_tag":[],"class_list":["post-11061","product","type-product","status-publish","has-post-thumbnail","product_cat-refrigeration-controller","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/comments?post=11061"}],"version-history":[{"count":1,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11061\/revisions"}],"predecessor-version":[{"id":11063,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product\/11061\/revisions\/11063"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media\/11062"}],"wp:attachment":[{"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/media?parent=11061"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_brand?post=11061"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_cat?post=11061"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/berndt-contec.de\/en\/wp-json\/wp\/v2\/product_tag?post=11061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}